Citation Regulations (N.S. Reg. 48/2025) (just regulations regs accbuiltenviro.htm)
N.S. Reg. 48/2025
Nova Scotia — Regulations
This consolidation is unofficial and is for reference only.
For the official version of the regulations, consult the original documents on file with the Office of the Registrar of Regulations , or refer to the Royal Gazette
Part II .
Regulations are amended frequently.
Please check the list of Regulations by Act to see if there are any recent amendments to these regulations filed with our office that are not yet included in this consolidation.
Although every effort has been made to ensure the accuracy of this electronic version, the Office of the Registrar of Regulations assumes no responsibility for any discrepancies that may have resulted from reformatting.
This electronic version is copyright ©
, Province of Nova Scotia , all rights reserved. It is for your personal use and may not be copied for the purposes of resale in this or any other form.
made under
Section 71 of the
S.N.S. 2017, c. 2
O.I.C. 2025-70 (effective March 6, 2025), N.S. Reg. 48/2025
Table of Contents
Please note: this table of contents is provided for convenience of reference and does not form part of the regulations.
Click here to go to the text of the regulations .
Citation
Definitions
Application
Public use
Part I - Technical Design Requirements
Barrier-free paths of travel
Tactile attention indicators
Curb ramps
Exterior ramps
Site selection evaluation
Exterior stairs
Accessible parking spaces in parking areas
On-street accessible parking spaces
Sidewalks
Temporary sidewalks
Pedestrian control signals
Placement of defibrillators
Lockers
Pools
Outdoor public eating areas
Benches
Campgrounds
Outdoor play spaces
Outdoor classrooms
Outdoor water bottle filling stations
Part II - Plan Development Requirements
Availability of plans
Development of plan for accessible outdoor spaces
Snow and ice control
Maintenance of parking areas
Plan for accessible entrance
Fire emergency evacuation plan
Citation
Regulations .
Definitions
2 In these regulations,
“accessible parking space” means a parking space designated for use by persons
who have an accessible parking permit;
“accessible pedestrian signal” means a device that assists pedestrians with visual
disabilities with the use of the “walk” and “don’t walk” signals when they are
attempting to cross a street;
“barrier-free entrance” has the same meaning as in the Nova Scotia Building Code ;
“beach access route” means a route that is constructed and intended for public use
and is used to access an area of a beach that is intended for recreational use by the
public from 1 or more of the following:
(
i) parking areas,
(ii) recreational trails,
(iii) exterior paths of travel,
(iv) amenities;
“clear floor space” means the amount of unobstructed floor or ground space
required to accommodate a person using a mobility device, such as a wheelchair,
scooter, cane, crutch or walker;
“colour contrast” means a 70% or greater difference in colour between a part of the
built environment and the surrounding surface;
“construction” means the phase of a project that involves the physical alteration or
modification of any aspect of the built environment and occurs after the planning
and design phases of the project;
“construction zone” means a physical area affected by construction;
“CSA B651” means CSA standard CSA/ASC B651-23, Accessible Design for the
Built Environment , as supplemented, amended, added to, replaced or superseded;
“curb ramp” means a sloped surface that allows people to move safely between
vehicular and pedestrian routes, but does not include driveways;
seated in a wheelchair pointing to the right and leaning forward as if in motion;
“firm and stable ground surface” means a floor or ground surface that does not
allow any of the following to sink into it:
(
i) canes,
(ii) crutches,
(iii) the wheels of mobility devices;
“frontcountry campground” means a campground or portion of a campground that
offers campsites that are primarily accessed by vehicle;
“highway” means
(
i) a public street, highway, sidewalk, lane, road or alley,
(ii) a part of a public park, a beach or other public property that is
accessible to the public for driving motor vehicles and not solely for
driving off-highway vehicles, or
(iii) privately owned property that is designed to be used by and is
accessible to the public for driving motor vehicles and not solely for
driving off-highway vehicles;
“illumination” means the combined amount and intensity of lighting, measured in
lux;
“installation” means the act of placing, applying, erecting, anchoring or securing an
aspect of the built environment;
a person seated in a wheelchair pointing to the right as depicted in ISO standard
ISO 7001, “Graphical symbols—Public information symbols”, as supplemented,
amended, added to, replaced or superseded;
“lux” means the standardised unit of measurement of illumination;
“multi-purpose recreation centre” means a building owned by a prescribed public
sector body that is intended for public use and that contains at least 2 of the
following:
(
i) a gymnasium,
(ii) a pool,
(iii) an ice pad,
(iv) a track,
(
v) a racket sport court,
(vi) a fitness room,
(vii) a community gathering room;
“municipality” means 1 of the following:
(
i) a regional municipality,
(ii) a municipality of a county or district,
(iii) a town,
(iv) a village, as continued under the Municipal Government Act ;
“ Nova Scotia Building Code ” has the same meaning as in the Nova Scotia Building
Code Regulations made under the Building Code Act ;
“on-street parking spaces” means 1 or more parking spaces located on a highway
for which a fee may or may not be charged;
“operating controls” includes, but is not limited to, any of the following:
(
i) handles,
(ii) locks,
(iii) faucets,
(iv) switches,
(
v) activation devices;
“outdoor classroom” means a dedicated area outside of a school that has fixed
seating and is intended to be used for instructional purposes by students and staff;
“outdoor play space” means an area intended for public use that includes play
equipment, such as swings or slides, or features, such as logs, rocks, sand or water,
that are designed and placed to provide play opportunities and experiences for
children and caregivers;
“outdoor public eating area” means an area that is intended for public use and to be
used to consume food, and includes public parks, hospital grounds and university
campuses;
“parking area” means an open area parking lot that is intended for public use and
to be used to temporarily park vehicles;
“pedestrian facilities” means a sidewalk, intersection, crosswalk, street, curb, curb
ramp, walkway, pedestrian right of way or other pedestrian pathway;
“prescribed public sector body” means an entity prescribed as a public sector body
“recreational trail” means a trail that is intended for public use and to be used for
recreational and leisure purposes and that is managed or operated by the
Government, a prescribed public sector body, a registered not-for-profit
organization that develops trails or an incorporated trail group;
“slip-resistant”, in relation to a surface, means the provision of sufficient frictional
counterforce to the forces exerted to permit safe movement;
“Temporary Workplace Traffic Control Manual” means the Temporary Workplace
Traffic Control Manual published by the Department of Public Works, as
supplemented, amended, added to, replaced or superseded.
Application
(1) These regulations apply to aspects of the built environment that are owned,
operated, maintained or controlled by a specific organization or a class of
organizations to which these regulations explicitly apply.
(2) The technical design requirements of these regulations apply to aspects of the built
environment that are any of the following:
(
a) newly constructed, with construction beginning on or after April 1, 2026;
(
b) newly installed, with installation beginning on or after April 1, 2026;
(
c) redeveloped, as required by these regulations, with construction beginning
on or after April 1, 2026.
(3) These regulations do not apply to any of the following:
(
a) federally regulated infrastructure;
(
b) aspects of the built environment that are governed by the Nova Scotia
Building Code Regulations made under the Building Code Act ;
(
c) aspects of the built environment that are governed by the Fire Safety
Regulations made under the Fire Safety Act ;
(
d) aspects of the built environment that are private residences with 3 or fewer
dwelling units.
Public use
4 For the purposes of these regulations, an aspect of the built environment that is primarily
designed or intended for public use has all of the following characteristics:
(
a) it is open to members of the public on a continuous, periodic or occasional
basis;
(
b) a fee may or may not be charged for its use.
Part I - Technical Design Requirements
Barrier-free paths of travel
(1) A barrier-free path of travel that is required by these regulations must meet all of
the following requirements:
(
a) it must have an unobstructed width of at least 1600 mm;
(
b) it must not have any opening that permits the passage of a sphere that is
more than 13 mm in diameter;
(
c) its elongated openings must be oriented approximately perpendicular to the
direction of travel;
(
d) it must be stable, firm and slip-resistant;
(
e) it must have a cross slope ratio of no more than 1:50;
(
f) it must be bevelled wherever there is a change in its level of no less than
6 mm and no more than 13 mm and the bevel must have a slope ratio of no
more than 1:2;
(
g) it must have a sloped surface or ramp at every change in its level that is
more than 13 mm;
(
h) it must have drainage that prevents the accumulation of ice and water;
(
i) it must not allow water from building downspouts or other drainage systems
to flow across it.
(2) A barrier-free path of travel may include ramps, passenger elevators, inclined
moving walks or passenger-elevating devices to overcome a difference in level.
Tactile attention indicators
6 A tactile attention indicator that assists persons with low vision or blindness by
signalling a change in elevation, a vehicular route or some other obstruction and that is
required by these regulations must meet all of the following requirements:
(
a) it must be a surface composed of truncated domes that meet all of the
following requirements:
(
i) they must have a base diameter of no less than 23 mm and no more
than 36 mm,
(ii) they must have a top diameter that is no less than 50% and no more
than 65% of the size of their base diameter,
(iii) they must have a height of no less than 4 mm and no more than
5 mm,
(iv) when walked on, they must make the surface they are on feel
noticeably different from the surrounding surface,
(
v) they must have a centre-to-centre distance of no less than 41 mm and
no more than 61 mm between them and adjacent domes,
(vi) they must have a base-to-base distance of at least 16.5 mm between
them and adjacent domes,
(vii) they must be arranged in a square grid pattern;
(
b) it must be slip-resistant;
(
c) it must be durable;
(
d) it must have a high colour contrast with adjacent surfaces.
Curb ramps
(1) A newly installed curb ramp must align with the direction of travel and meet all of
the following requirements:
(
a) it must have a clear width of at least 1200 mm, exclusive of any flared
sides;
(
b) it must have a running slope ratio of no less than 1:15 (6.66%) and no more
than 1:10 (10%);
(
c) it must have a cross slope ratio of no more than 1:50;
(
d) it must have flared sides that have a slope with a ratio of no more than 1:10,
measured parallel to the curb line;
(
e) if it is located at a pedestrian crossing, it must have tactile attention
indicators that meet all of the following requirements:
(
i) they must be no less than 600 mm and no more than 650 mm in
depth,
(ii) they must extend across the full width of the curb ramp,
(iii) they must be set back no less than 300 mm and no more than
350 mm from the curb edge.
(2) An existing curb ramp immediately adjacent to a portion of sidewalk that is being
replaced must meet the requirements of subsection (1).
Exterior ramps
8 A newly constructed exterior ramp that is not connected to a building and that is
connected to a barrier-free path of travel must meet all of the following requirements:
(
a) it must have a width of at least 1200 mm;
(
b) it must have a running slope ratio of no less than 1:20 (5%) and no more
than 1:12 (8.33%);
(
c) it must have a horizontal distance between level landings that is no more
than 9000 mm;
(
d) it must have level landings that are at least 1700 mm long by 1700 mm
wide at all of the following locations:
(
i) at the top and bottom of the ramp,
(ii) at all changes of ramp direction.
Site selection evaluation
9 Prescribed public sector bodies and the Government must consider all of the following
characteristics when evaluating new sites for an outdoor space primarily designed for
public use or for a building primarily designed for public use:
(
a) the availability of public transportation at the site;
(
b) the proximity of the site to pedestrian facilities;
(
c) the availability of accessible parking spaces at the site;
(
d) the availability of safe drop-off locations at the site;
(
e) the proximity of the site to the community and clientele that the space or
building is intended to serve;
(
f) the site’s topography.
Exterior stairs
(1) Newly constructed exterior stairs that are not associated with a building and that
are connected to a barrier-free path of travel must meet all of the following
requirements:
(
a) each flight of the stairs must have uniform risers and runs;
(
b) they must have a tread surface finish that is slip-resistant;
(
c) they must have a rise between successive treads that is no less than 125 mm
and no more than 180 mm;
(
d) they must have a run between successive steps that is at least 280 mm;
(
e) they must have closed risers;
(
f) they must have a tread nosing projection of no more than 38 mm and no
abrupt undersides;
(
g) they must have colour contrast markings that extend across the full tread
width of the leading edge of each step;
(
h) they must have a clear headspace of at least 2100 mm;
(
i) they must have tactile attention indicators that are built into or applied to the
walking surface and that meet all of the following requirements:
(
i) they are located at the top of each flight of the stairs,
(ii) they extend across the full tread width to a depth of at least 610 mm
and commence 1 tread depth from the edge of the stairs;
(
j) they must have handrails on both sides that comply with the handrail
requirements in Clause 5.4.4 of CSA B651;
(
k) they must have a guard that meets all of the following criteria:
(
i) it is at least 920 mm in height, measured vertically to the top of the
guard from a line drawn through the outside edges of the stair
nosings,
(ii) it is 1070 mm in height, measured from the surface of the landing,
(iii) it is on each side of the stairway wherever the difference in elevation
between ground level and the top of the stair is more than 600 mm.
(2) Despite clause (1)(k), a guard is not required on any side of the stairs where there
is a wall.
Accessible parking spaces in parking areas
(1) Subject to subsection (4), this
Section applies to all new and redeveloped parking
Nova Scotia Building Code Regulations made under the Building Code Act .
(2) The number of accessible parking spaces that parking areas must include is as set
out in the following table:
Number of parking spaces
Number of accessible parking
spaces required
1 to 10
11 to 35
36 to 50
51 to 99
each additional set of up to 50
spaces that is in excess of 100 spaces
1 additional space
(3) An accessible parking space must meet all of the following requirements:
(
a) it must be designed to include a barrier-free path of travel that extends to the
entrance of the parking area and meets all of the following requirements:
(
i) it must have vertically oriented signage that features a colour contrast
at every point on it where a pedestrian crosses traffic,
(ii) it must have an average illumination of 50 lux and every part of it
must have an illumination of at least 10 lux,
(iii) if it requires a curb ramp, the curb ramp must have tactile attention
indicators and colour contrasting elements,
(iv) if it is on a hardened surface, such as concrete or asphalt, it must
have pavement markings;
(
b) it must be at least 2600 mm wide;
(
c) it must be accessible by an access aisle that is at least 2000 mm wide and
that is shared by no more than 1 adjacent parking space;
(
d) it must be clearly marked with the International Symbol of Access or the
Dynamic Symbol of Access;
(
e) it must be identified by a sign located at least 1500 mm above ground level.
(4) This
Section does not apply to parking areas that are exclusively used by 1 or more
of the following types of vehicles:
(
a) buses;
(
b) delivery vehicles;
(
c) law enforcement vehicles;
(
d) medical transportation vehicles, such as ambulances;
(
e) impounded vehicles;
(
f) vehicles parked in a carpool parking lot with space for no more than 15
vehicles.
(5) A parking area is considered to be redeveloped if its parking spaces have been
redistributed within the existing parking area or more than 50% of the parking area
has been resurfaced.
On-street accessible parking spaces
(1) When a prescribed public sector body or the Government is developing on-street
parking spaces, it must consult with persons with disabilities on the need for,
location of and design of accessible parking spaces.
(2) A new accessible on-street parking space must meet all of the following
requirements:
(
a) it must be at least 2600 mm wide and at least 5500 mm long;
(
b) it must have an access aisle that is at least 2000 mm wide directly behind it;
(
c) for an on-street parking space that is adjacent to a curb, it must include a
barrier-free path of travel to a curb ramp.
Sidewalks
(1) A prescribed public sector body or the Government must comply with all of the
following when designing a sidewalk:
(
a) Geometric Design Guide for Canadian Roads published by the
Transportation Association of Canada, as supplemented, amended, added to,
replaced or superseded;
(
b) for pedestrian crossing components, Clause 8.3.5 of CSA B651.
(2) Street furniture, signage, banners, flowerpots, waste receptacles and any other
objects placed on sidewalks must not obstruct a barrier-free path of travel.
Temporary sidewalks
(1) This
Section applies to all temporary sidewalks installed or re-installed on or after
April 1, 2026, including those that are installed to accommodate sidewalk cafés,
restaurant patios and construction zones.
(2) A temporary sidewalk must meet all of the following requirements:
(
a) it must have a firm and level surface;
(
b) it must be slip-resistant;
(
c) it must not impede pedestrian movement or safety;
(
d) it must be at least 1600 mm wide;
(
e) it must have a barrier on the side that is located next to vehicular travel that
is at least 810 mm high and that features reflective elements;
(
f) if it is covered, it must have at least 2100 mm of clearance.
(3) If a temporary sidewalk is required due to construction, pedestrian signage must be
installed in accordance with the Temporary Workplace Traffic Control Manual.
(4) If lighting is placed on a temporary sidewalk, it must not do any of the following:
(
a) interfere with a traffic signal light, traffic control sign or traffic device;
(
b) obstruct or interfere with the movement of motorists or pedestrians;
(
c) produce or cause glare that is visible to motorists, pedestrians or
neighbouring premises;
(
d) move or appear to move.
(5) If the requirements of this
Section cannot be achieved because of the nature and
location of a construction zone, a crosswalk to a barrier-free sidewalk must be
installed before any construction-related obstruction occurs.
(6) If access to the barrier-free entrance of a property is not available due to a
temporary sidewalk, alternative barrier-free access to the property entrance must be
provided.
Pedestrian control signals
15 A newly installed or replaced traffic control signal system with pedestrian control signals
must include accessible pedestrian signals that meet the standards in the Manual of
Uniform Traffic Control Devices for Canada published by the Transportation
Association of Canada, as supplemented, amended, added to, replaced or superseded.
Placement of defibrillators
(1) A defibrillator installed by a prescribed public sector body or the Government in a
building that has a barrier-free entrance and is primarily designed for public use
must meet all of the following requirements:
(
a) it must be located on a wall located next to a barrier-free path of travel;
(
b) it must be located next to a clear floor space that is at least 820 mm wide
and 1390 mm long;
(
c) it must be mounted no more than 1200 mm above floor level.
(2) Despite clause (1)(c), if the defibrillator protrudes more than 100 mm from the
wall, it must meet 1 of the following requirements to ensure that it is cane
detectable:
(
a) it must be mounted no more than 685 mm above floor level;
(
b) it must have a tactile attention indicator of at least 600 mm wide by 600 mm
long attached to the floor in front of it.
Lockers
(1) If new lockers are installed in a multi-use recreation centre, they must include
accessible lockers that meet all of the following requirements:
(
a) they must be located next to a barrier-free path of travel;
(
b) they must have a clear floor space in front of them that is at least 820 mm
wide by 1390 mm long when the locker door is open;
(
c) they must have operating controls that are mounted no less than 400 mm
and no more than 1200 mm above floor level;
(
d) they must be operable with 1 hand in a closed fist position and without
requiring tight grasping, pinching with fingers or twisting of the wrist;
(
e) they must be located in close proximity to an accessible bench that meets
the requirements of
Section 20;
(
f) they must not allow things to be stored on top of them.
(2) The number of accessible lockers that must be provided for the purposes of
subsection (1) is as set out in the following table:
Number of lockers
Number of accessible lockers
required
1 to 15
16 to 45
46 to 100
101 to 150
each additional set of up to 50
lockers that is in excess of 150
lockers
1 additional locker
Pools
18 A newly constructed swimming pool that is outdoors or indoors and that is intended for
public use must meet all of the following requirements:
(
a) it must have all of the following means of pool access:
(
i) a sloped entry with a ratio of no more than 1:20,
(ii) a pool lift;
(
b) it must have colour contrast along its edges and on its access points;
(
c) all of its edges must be cane detectable.
Outdoor public eating areas
(1) A new outdoor public eating area installed by a prescribed public sector body or
the Government must meet all of the following requirements:
(
a) for an outdoor public eating area with more than five tables, at least 20% of
its tables must be accessible;
(
b) for an outdoor public eating area with five or fewer tables, it must have at
least 1 accessible table.
(2) The tables referred to in subsection (1) must meet all of the following
requirements:
(
a) they must be located next to a barrier-free path of travel;
(
b) they must be located on a firm and stable ground surface that extends at
least 2000 mm outwards from each of their sides;
(
c) they must have a knee clearance that is at least 820 mm wide, 480 mm deep
and 685 mm high.
(3) Subsections (1) and (2) apply when new tables are installed in an existing outdoor
eating area.
Benches
20 A new bench installed by a prescribed public sector body or the Government in an area
intended for public use that is located next to a barrier-free path of travel must meet all
of the following requirements:
(
a) it must be located on a firm and stable ground surface;
(
b) it must be located next to a clear floor space that is at least 820 mm wide by
1390 mm long and that is not part of the barrier-free path of travel;
(
c) it must have a seat that is no less than 430 mm and no more than 485 mm
above the ground;
(
d) it must be free of sharp or abrasive edges;
(
e) there must be a colour contrast between the ground surface of its seating
area and the surrounding area.
Campgrounds
(1) A new frontcountry campground must include the number of accessible campsites
as set out in the following table:
Number of campsites
Number of accessible campsites
required
1 to 30
31 to 50
51 to 150
151 to 300
each additional set of up to 50
campsites that is in excess of 300
campsites
1 additional campsite
(2) An accessible campsite must meet all of the following requirements:
(
a) it must be located on a firm and stable ground surface;
(
b) it must have a barrier-free path of travel to
(
i) an accessible potable water station, and
(ii) an accessible washroom;
(
c) it must have an accessible picnic table with a knee clearance that is at least
820 mm wide, 480 mm deep and 685 mm high.
(3) An accessible potable water station described in subclause (2)(b)(
i) must meet all
of the following requirements:
(
a) it must be located next to a clear floor space that is at least 820 mm wide by
1390 mm long;
(
b) it must be operable with 1 hand in a closed fist position and without
requiring tight grasping, pinching with fingers or twisting of the wrist;
(
c) it must have a knee clearance that is at least 820 mm wide, 480 mm deep
and 685 mm high;
(
d) it must be operable at a height of no more than 1200 mm above ground
level.
(4) A campground is considered to be new if it is newly open to the public or if it has
been closed for a period of 12 months or more before reopening.
Outdoor play spaces
22 A new outdoor play space installed by a prescribed public sector body or the
Government must meet all of the following requirements:
(
a) it must contain a barrier-free path of travel to
(
i) any associated buildings, and
(ii) any pedestrian facilities;
components, for children and caregivers with various disabilities into its
design;
(
c) it must be located on a firm and stable ground surface;
(
d) it must include sufficient clearance to allow children and caregivers to
manoeuvre in and around the outdoor play space.
Outdoor classrooms
(1) A new or redeveloped outdoor classroom attached to a public school must meet all
of the following requirements:
(
a) there must be a barrier-free path of travel from the public school to it;
(
b) it must be located on a firm and stable ground surface with a turning
diameter of at least 2250 mm.
(2) An outdoor classroom is considered to be redeveloped if the path of travel from the
school to the classroom has been replaced or 50% or more of the classroom’s
seating has been replaced.
Outdoor water bottle filling stations
24 A new outdoor water bottle filling station installed by the Government or a prescribed
public sector body must meet all of the following requirements:
(
a) it must be located next to a barrier-free path of travel;
(
b) it must be located next to a clear floor space that is at least 820 mm wide by
1390 mm long;
(
c) it must be equipped with operating controls that
(
i) are operable with 1 hand in a closed fist position and without
requiring tight grasping, pinching with fingers or twisting of the
wrist, or
(ii) activate automatically;
(
d) it must have a knee clearance that is at least 820 mm wide, 480 mm deep
and 685 mm high;
(
e) it must be operable at a height of no more than 1200 mm above ground
level.
Part II - Plan Development Requirements
Availability of plans
25 All plans that are required to be prepared for the purposes of these regulations must be
made publicly available no later than April 1, 2026.
Development of plan for accessible outdoor spaces
recreational trails, parks, beach access routes and outdoor play spaces in Nova
Scotia and requires that all of the following be located in each geographic region
specified by the plan by 2030:
(a) 1 accessible recreational trail;
(b) 1 accessible park;
(c) 1 accessible beach access route, if applicable;
(d) 10 accessible public outdoor play spaces.
(2) The Government must seek input from persons with disabilities, municipalities and
subject matter experts when developing the plan required by subsection (1).
(3) All of the following characteristics of a region must be considered when
determining whether the region should be a specified geographic region:
(
a) the population base;
(
b) the geographic nature of the land;
(
c) the existing infrastructure, including access to public transportation;
(
d) the distance Nova Scotians currently have to travel from their primary
residence to reach all of the following or will have to travel from their
primary residence to reach all of the following if they are established in the
region:
(
i) an accessible recreational trail,
(ii) an accessible park,
(iii) an accessible beach access route,
(iv) an accessible public outdoor play space.
(4) The plan required by subsection (1) must be made publicly available.
Snow and ice control
27 A prescribed public sector body and the Government must make their snow and ice
control standards for pedestrian facilities publicly available.
Maintenance of parking areas
(1) An organization that owns a parking area must develop a regular maintenance plan
that covers all of the following:
(
c) the painting of parking space lines;
(
d) the maintenance of the surface of the parking area, including pedestrian
pathways;
(2) The plan required by subsection (1) must be made publicly available.
Plan for accessible entrance
(1) A building with 1 or more barrier-free entrances must have a plan to ensure that all
of the entrances remain free of physical obstruction.
(2) For the purposes of this Section, “physical obstruction” includes impassable
barriers on or above pathways that prevent people from using a barrier-free
entrance.
(3) The plan required by subsection (1) must be made publicly available.
Fire emergency evacuation plan
(1) An owner of a residential building with 4 or more units and an occupancy of 10 or
fewer people must post an emergency evacuation plan near the principal entrance
of the building that meets all of the following requirements:
(
a) it must contain emergency procedures to follow if there is a fire in the
building that include all of the following:
(
i) procedures for notifying the fire department,
(ii) procedures for instructing occupants on the procedures to follow
when the fire is detected,
(iii) procedures for evacuating occupants, including special procedures for
evacuating persons with disabilities requiring assistance,
(iv) procedures for confining, controlling and extinguishing the fire;
(
b) it must identify the individuals responsible for carrying out the evacuation;
(
c) it must identify the types of training that the individuals described in clause
(
b) must receive to carry out their duties under the plan.
(2) The evacuation plan required by subsection (1) must be reviewed by the building
owner or operator at intervals of no more than 12 months to ensure that the plan
accounts for changes in the use and other characteristics of the building.
Legislative History
Reference Tables
N.S. Reg.
48/2025
Note: The
information in these tables does not form part of the regulations and is
compiled by the Office of the Registrar of Regulations for reference only.
Source Law
following regulations:
N.S.
Regulation
In force
date*
How in force
Royal Gazette
Part II Issue
48/2025
Mar 6, 2025
date specified
Mar 21, 2025
The following regulations are not
yet in force and are not included in the current consolidation:
N.S.
Regulation
In force
date*
How in force
Royal Gazette
Part II Issue
*See subsection 3(6) of the Regulations Act for
rules about in force dates of regulations.
Amendments by Provision
ad. = added
am. = amended
fc. = fee change
ra. = reassigned
rep. = repealed
rs. = repealed and substituted
Provision affected
How affected
. ........................................................
Note that changes to headings are not
included in the above table.
Editorial Notes and Corrections
Note
Effective
date
Repealed and Superseded
N.S.
Regulation
Title
In force
date
Repealed
date
Note: Only
regulations that are specifically repealed and replaced appear in this
table. It may not reflect the entire
history of regulations on this subject matter.