B.C. Reg. 203/2006, deposited July 13, 2006, pursuant to the ENERGY EFFICIENCY ACT [Section 6 (2)]. Order in Council 503/2006, approved and ordered July 13, 2006.
On the recommendation of the undersigned, the Lieutenant Governor, by and with the advice and consent of the Executive Council, orders that the Energy Efficiency Standards Regulation, B.C. Reg. 389/93, is amended as set out in the attached Appendix.
— R. NEUFELD, Minister of Energy, Mines and Petroleum Resources; G. CAMPBELL, Presiding Member of the Executive Council.
Appendix
Section 7 of the Energy Efficiency Standards Regulation, B.C. Reg. 389/93, is amended
(
a) in subsection (2) by striking out "items 1 and 26"
and substituting "item 1",
(
b) in subsection (6) by striking out "8,", and
(
c) by adding the following subsections:
(11) For items 8, 26 and 40 of
Schedule 1, the minimum efficiency level must not be less than the value set out in
Column 3 for the energy device opposite in Column 1, commencing on the date set out opposite in
Column 4.
(12) For items 37 and 38 of
Schedule 1, the efficiency level must be as described in
Column 3 for the energy device opposite in Column 1, commencing on the date set out opposite in
Column 4.
(13) For item 39 of
Schedule 1, the energy device described in
Column 1 must be tested and rated according to the standard set out in Column 2, and a label indicating the rating must be affixed to the energy device so that it is easily and readily seen without the need to remove any covering.
2 Sections 8 (3) and (4) and 9 are repealed.
Schedule 1 is amended
(
a) by deleting item 8 and replacing it with item 8 as set out in the attached Schedule,
(
b) by adding new items 37 to 40 as set out in the attached Schedule,
(
c) by striking out "British Thermal Units per hour"
wherever it appears and substituting "BTU/h", and
(
d) by adding the following note at the end:
BTU/h = British Thermal Units per hour.
Schedule
Column 1
Column 2
Column 3
Column 4
Gas-fired forced air furnaces,
other than furnaces for
recreational vehicles and
replacement furnaces in
pre-existing residential dwellings,
for use with propane and natural
gas having input rating less than
66 kilowatts (225 000 BTU/h).
CGA P.2-91
Testing Method for Measuring
Annual Fuel Utilization
Efficiencies of Residential
Furnaces and Boilers
AFUE = 90%
Jan 1, 2008
Manufactured fenestration
products including windows,
skylights and doors.
CSA A440.2-04
Energy Performance of Windows
and Other Fenestration Systems
NFRC 100-2004
Procedure for Determining
Fenestration Product U-Factors
Maximum U-value
= 2.0 W/(m 2 •
K) Jan 1, 2009
Thermostats used for line-voltage
(120-240V) switching of a controlled
resistive heating load including
wall-mounted, built-in and two
component thermostats.
CSA C828-06
Performance Requirements for
Thermostats Used with Individual
Room Electric Space Heating
Devices
Maximum Differential
= 0.5ºC
Maximum droop
= 2ºC
Jan 1, 2007
Gas fireplaces including inserts
and free-standing stoves, for use
with propane and natural gas.
CAN/CSA P.4.1-02
Testing Method for Measuring
Annual Fireplace Efficiency
Jan 1, 2007
Natural gas and propane fired
boilers having input rating
greater than 88 kilowatts
(300 000 BTU/h).
ANSI Z21.13-2004/CSA 4.9-2004
Gas-Fired Low Pressure Steam
and Hot Water Boilers
GAMA BTS-2000
Method to Determine Efficiency of
Commercial Space Heating Boilers
Combustion efficiency
= 80%
Jan 1, 2007