British Columbia Gazette Part II — B.C. Reg. 249/2004
B.C. Reg. 249/2004
British Columbia — Gazette
Copyright © Queen's Printer,
Victoria, British Columbia, Canada
Licence
Disclaimer
Volume 47, No. 12
B.C. Reg. 249/2004
The British Columbia Gazette,
Part II
June 15, 2004
B.C. Reg. 249/2004, deposited June 9, 2004, pursuant
to the FIRE SERVICES ACT [Section 47 (2)]. Ministerial
Regulation M224/2004, dated June 8, 2004.
I, Murray Coell, Minister of Community, Women's and Aboriginal
Services, order that the British Columbia Fire Code, B.C. Reg. 318/2003,
is amended as set out in the attached schedule.
— M. COELL, Minister
of Community, Aboriginal and Women's Services.
Schedule
THE BRITISH COLUMBIA FIRE CODE
1. Replace
Article 2.7.1.3. with
2.7.1.3. Occupant Load
1) The maximum permissible occupant load
for any room shall be calculated on the basis of the lesser of
a) 0.4 m 2 of net floor space per occupant, or
b) the occupant load for which means of egress
are provided.
(See Appendix A.)
2) The number of persons permitted to enter a
room shall not exceed the maximum occupant load calculated in conformance
with Sentence (1).
2. Replace Appendix Note A-2.7.1.3. (3) with Appendix Note A-2.7.1.3. (1) as follows
A-2.7.1.3.
(1) The British Columbia Fire Code uses two criteria to determine
the maximum permissible occupant load in existing buildings: the exit capacity,
and the total clear space per person. Assuming that exit capacity is sufficient,
the value of 0.4m 2 /person ensures that a crowd of people will be
able to move steadily toward the exits.
Table 3.1.16.1. in the British Columbia Building Code should not be used to
determine maximum permissible occupant load for rooms or spaces in existing
buildings. Table 3.1.16.1. is intended to allow a building designer to
calculate a minimum occupant load for the purpose of designing certain building
features, such as means of egress and fire alarm systems. The designer may choose
to design for more or fewer persons, in which case the actual design occupant
load must be posted in a conspicuous location. In an existing building, the
process must be calculated in reverse, from the measured exit capacity, or other
building features, to a maximum permissible occupant load. The result of the
calculation may not be, and is not intended to be, consistent with values obtained
using Table 3.1.16.1.
Net floor space referred to in Clause (
a) is the floor space in a room excluding areas occupied by structural features and fixtures, such as tables, furnishings or equipment. In certain assembly occupancies, where the number and type of furnishings may change according to the nature of the function taking place, it may be appropriate to calculate maximum occupant loads for each of the different functions anticipated.
It should also be noted that
Article 2.1.3.1. of this Code requires fire alarm
systems to be installed in conformance with the British Columbia Building Code.
This means that if the occupant load determined by Sentence 2.7.1.3.
(1) exceeds that for which a fire alarm system is required by the British Columbia
Building Code, a fire alarm system must be provided in the building.